Data centre infrastructure · Sydney

The hardware that powers your data centre.

OTK Technologies supplies and installs modular data halls, cages, racks, PDUs, turbo diesel generators and battery energy storage (BESS). We also provision SD-WAN, IPSec and out-of-band networks, and maintain everything we install.

Working with data centre operators, colocation and GPU cloud providers and enterprises.

Power path from utility, generator and battery storage through the main switchboard to PDUs in racks inside a cage within a modular data hall. OTK supplies and installs each stage. UTILITYGrid supply GENERATORTurbo diesel BESSBattery storage MAIN SWITCHBOARD ATS · A & B outputs MODULAR DATA HALL CAGE FEED A FEED B
What OTK supplies and installs, from power source to rack PDU

What we supply & install

From the generator to the rack, and out to your network.

We source the equipment, deliver it, install it and commission it, so the space is ready when your hardware arrives. Every item below can be supplied and installed as a package or on its own.

White space

Halls, cages & racks

Modular data halls

Prefabricated data hall modules delivered, set in place and fitted out, adding capacity faster than a traditional build.

Prefabricated modules · containment · on-site fit-out

Cages

Secure single-tenant cages built to your footprint, with partitions, lockable doors and room to grow.

Mesh partitions · lockable doors · access-control ready

Racks & containment

Cabinets installed, levelled and bonded, with aisle containment, blanking and cable management.

42U–52U cabinets · hot/cold aisle · cable trays

Power

Distribution, backup & storage

PDUs

Rack power distribution supplied and fitted on dual feeds, with load planned per cabinet for high-density compute.

Metered / switched · A+B feeds · C13/C19 outlets

Turbo diesel generators

Standby generator sets sized to your load, delivered, placed and integrated with the switchboard and transfer switching.

Standby rating · ATS integration · fuel systems
Baudouin data centre range

Battery energy storage (BESS)

Battery systems that carry the load through outages and generator start-up, and can reduce peak demand from the grid.

Ride-through · peak shaving · energy management

Network

Connectivity & access

SD-WAN provisioning

Edge appliances installed and configured to link your data centre space with offices, clouds and other sites over managed paths.

Dual-uplink edge · path policies · QoS

IPSec site-to-site VPN

Encrypted tunnels between your racks and your networks, built on a firewall we configure, document and hand over.

IKEv2 · AES-256 · tunnel failover test

Out-of-band management

A separate management network and console access so equipment can be reached even when the primary path is down.

OOB switch · serial console · 4G fallback option

Delivery

Supply, install & support

Supply & logistics

Equipment sourced from established vendors, with freight, site access, rigging and placement handled for you.

Vendor sourcing · freight · cranage & rigging

Installation & commissioning

Installed by licensed trades and tested under load before handover, with full documentation.

Load bank testing · A/B failover · as-built drawings

Maintenance

Scheduled servicing of the equipment we install, plus fault response and parts replacement.

See the schedule below

Generator brands we supply

Baudouin data centre generator sets

Baudouin has been building engines in France since 1918. Its M33, M55 and M61 range is designed for data centre standby power, from single sets to multi-megawatt plant. We supply, place and commission them with your switchboard, fuel system and BESS.

  • Dual redundant starter motors as standard
  • Load acceptance to ISO 8528 performance class G3
  • Data centre ratings (DCR and DCP)
  • Controller with AMF and synchronising, Ethernet remote monitoring and BMS/PLC integration
  • Suitable for HVO renewable diesel
  • Options: base fuel tank for extended running, fuel polishing, acoustic and 2-hour fire-rated enclosures
Engine platforms
ModelUp to
20M332,500 kVA
12M553,125 kVA
16M554,125 kVA
20M555,000 kVA
20M616,250 kVA

Manufacturer figures. Output depends on rating type, frequency and site conditions; we size each set to your load.

How we work

From signed order to a powered hall.

Every build is planned around a known load, rack count and handover date. We work to that plan from day one and report against it.

  1. Scope

    We confirm the IT load, rack count, connectivity needs and site constraints with your team.

    Scope of works
  2. Design

    Hall and cage layout, power single-line, generator and BESS sizing, and network topology, reviewed with you before we order.

    Design pack
  3. Supply

    We procure the equipment, track lead times and manage delivery, rigging and placement on site.

    Delivery schedule
  4. Install & commission

    Install, connect and test: generator load bank, BESS commissioning, A/B feed failover, and tunnel and SD-WAN path tests.

    Test & handover report
  5. Maintain

    Scheduled servicing and fault response for as long as you need it.

    Service reports

Who we work with

Built for the people who run compute.

We take on a full build or a single item, working alongside your facility provider and your own engineers.

Operators

Data centre operators

  • Modular data halls to add capacity
  • Generators and BESS for backup and ride-through
  • Ongoing maintenance of power plant

Providers

Colocation & GPU cloud providers

  • Cages, racks and containment for each tenant
  • High-density PDUs on A+B feeds
  • Fit-out timed to customer go-live

Tenants

Enterprises & tenants

  • Racks and PDUs in your colocation space
  • SD-WAN and IPSec links back to your sites
  • Out-of-band access and remote maintenance

One team for space, power and network. Fewer handoffs between trades, and one set of documents at handover.

Maintenance

A typical maintenance schedule.

Each customer's schedule is set in their service agreement and follows the equipment manufacturers' requirements. This is the baseline we start from.

CheckWhat we doFrequencyEquipment
Generator run testStart and run the generator, check transfer switching, log alarms, fluid levels and battery charge.MonthlyGenerator
Generator load bank testRun the set under load to confirm it delivers rated output, then service filters and fluids.AnnuallyGenerator
Fuel quality & storageSample and test stored diesel, inspect tanks and fuel lines.6-monthlyGenerator
BESS health reviewReview battery management alarms, state of health and cell temperatures.MonthlyBESS
BESS inspectionThermal scan of connections, inspect enclosures, cooling and fire protection.6-monthlyBESS
PDU load & phase balanceRead per-outlet and per-phase load, flag cabinets nearing their power budget.MonthlyPDU
Tunnel & path healthReview IPSec tunnel stability and SD-WAN path performance, test failover.QuarterlyNetwork
Network firmwareApply vendor updates to SD-WAN edges, firewalls and OOB devices in an agreed change window.Per releaseNetwork
Racks, cages & containmentCheck containment seals, blanking, door locks and cable management.QuarterlyWhite space

Response times and support hours are defined per agreement.

Contact

Tell us about your deployment.

Share your IT load, rack count, connectivity needs and timeline. We'll come back with a scope of works and equipment options.